Basic Info.

Model NO.
DN15~32
Principle
Speed of Water Meter
Medium Pressure
General Water Meter
Work Environment
Dry Water Meter
Stucture
Intelligent IC Card
Wireless Communication
Nb-Iot or GPRS
Transport Package
Export Carton, Plastic Pallet
Specification
Brass body, brass connectors
Trademark
OEM
Origin
Ningbo, China
HS Code
9028201000
Production Capacity
30000PCS/Month

Product Description

Photoelectric Direct Reading Remote RS485 M-Bus Water Meter
Remote meter reading, stable performance, accurate meter reading, high measurement accuracy
.

Applicable to: all kinds of buildings and residential water supply measurement.
It can be combined with remote control valve, data collector, concentrator and management software to build "water metering intelligent management system" to realize water metering intelligent management.

Description

LXSGY/R type direct-reading remote water meter is a kind of measuring instrument that adopts photoelectric technology to measure the total volume of water flowing through the tap water pipeline.That new water meter, with new technology, novel design, reasonable, excellent material selection, beautiful appearance, precision assembly, easy maintenance.

Features
 
  1. The non-contact sensor does not affect the original performance of the mechanical water meter
  2. The infrared countermeasure is adopted to enhance the ability of anti-jamming.Non-mechanical contact mode, will not cause the phenomenon of random code reading due to mechanical loosening.
  3. Low power consumption design, only when reading power supply.
  4. Special coding mode, no dead zone of reading, word wheel rotation to any position can keep the mechanical reading and electronic reading consistent.
  5. Adopting advanced data coding and checking method, communication reliability is high
  6. Can be combined with the meter reading system, the establishment of remote meter reading management system, truly achieve meter reading automation

MAIN TECHNICAL DATA
 
Meter size Dia DN (mm) Class Q4 Q3 Q2 Q1
m3/h L/h
DN15 2 3.125 2.5 50 31.25
DN20 5 4 80 50
DN25 7.875 6.3 126 78.75
DN32 12.5 10 2 125


Working condition:
  1. Water temperature: no more than 30 ºC, 90 ºC hot water).
Pressure: no more than 1Mpa
working environment: class B.
  1. Sensitivity level of upstream flow field :U10;
Downstream flow field sensitivity level :D5.
  1. Transmission mode is divided into RS-485 and MBUS
  2. Communication transmission rate: 2400bps;
Maximum communication transmission distance: 1000m

INDICATING ERROR
 
At low zone is ±5% from minimum flow rate (qmin) to transitional flow rate (qt) exclusive boundary
At high zone is ±2% from transitional flow rate (qt) to overload flow rate(qs)
 
DIMENSIONS AND WEIGHT





 
Size Length L Length L1 Width B Height H Connecting Thread Weight connecting line
mm d D Kg m
15 258 165 90 120 R1/2 G3/4 1.4 0.9
20 294 190 90 120 R3/4 G1 1.7 0.9
25 345 225 90 120 R1 G1 1/4   0.9
32 350 225 90 120 R1 1/4 G1 1/2   0.9


Installation and maintenance
 
  1. Choose the diameter of water meter, should be decided according to pipe and use flow rate, and unfavorable use hot water
  2. The installation location should avoid exposure, freezing, pollution and water flooding for easy disassembly and meter reading
  3. The meter must be installed horizontally so that it literally faces up and that the arrow on the case is in the same direction as the flow
  4. Before the new installation of pipes, be sure to wash the stones, silt, hemp and other debris in the pipe clean before installing the water meter, so as not to cause water meter failure
  5. To measure correctly, the tap should be higher than the meter
  6. Maximum pressure loss: 0.063Mpa

FACTORY:

Photoelectric Direct Reading Remote RS485 M-Bus Water MeterPhotoelectric Direct Reading Remote RS485 M-Bus Water MeterPhotoelectric Direct Reading Remote RS485 M-Bus Water MeterPhotoelectric Direct Reading Remote RS485 M-Bus Water MeterPhotoelectric Direct Reading Remote RS485 M-Bus Water MeterPhotoelectric Direct Reading Remote RS485 M-Bus Water MeterPhotoelectric Direct Reading Remote RS485 M-Bus Water MeterPhotoelectric Direct Reading Remote RS485 M-Bus Water Meter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
102
Year of Establishment
2016-11-08